Summary for Test 2016-07-13-11-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209918
DEA: 07274804
EFIS: 0700000516
DIST-CO-RTE-PM07-LA-18-0.2
Award Date12/09/2014
Closeout Date01/15/2018
Work DescriptionREPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS.
Location DescriptionLOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD
QA Service Level1 (Verified on 01/08/2015)

Sample Information

Sample Taken Date07/13/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2016
Sample typeQuality Assurance A brief description of the sampleDouble Barrel Zap Screwlok
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed bySarah Last name of sampler or witnessed byHartz
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarsplice Arceiormittal Nucor Transportation Laboratory (TL) NumberC866877
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerArcelormittal Nucor
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size#5 Coupler ModelDouble Barrel Zap
Coating StandardsASTM A775 Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)5119 Rebar Heat Number(s)1523113, PL1520843351
Rebar Size 2 NA Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-07-13-11
DIME Test ID: 2016-07-13-11-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-07-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/22/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
133#5/16mm0.312639085130Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/25/2016