Summary for Test 2016-06-13-10-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 211091 DEA: 081G1004 EFIS: 0815000125 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-36.5/42.6 |
Award Date | 02/25/2016 |
Closeout Date | 10/26/2016 |
Work Description | REPLACE ASPHALT CONCRETE SURFACING AND SLURRY SEAL |
Location Description | REPLACE ASPHALT CONCRETE SURFACING AND SLURRY SEAL |
QA Service Level | 1 (Verified on 05/03/2016) |
Sample Information
Sample Taken Date | 06/13/2016 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/17/2016 |
Sample type | Department Acceptance | A brief description of the sample | Aggregate Type III for Slurry Seal |
The quantity of what the sample constitutes | 1 Bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Mohammad | Last name of sampler or witnessed by | Abuelkhair |
Title of sampler | TE | Telephone number of sampler | Unknown |
Laboratory sample identification | 6255B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Chandler Corona | Transportation Laboratory (TL) Number | C 985243 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Job Site |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | fine |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2016-06-13-10
DIME Test ID: 2016-06-13-10-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-10-15
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Danilo Ferrer
Date of test: 06/21/2016
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 90 %
Cumulative percent passing the #8 sieve: 59 %
Cumulative percent passing the #16 sieve: 40 %
Cumulative percent passing the #30 sieve: 28 %
Cumulative percent passing the #50 sieve: 19 %
Cumulative percent passing the #100 sieve: 14 %
Cumulative percent passing the #200 sieve: 10 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/15/2019 ✔