Summary for Test 2022-06-01-29-1
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
---|---|
DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
Award Date | 05/01/2019 |
Closeout Date | 02/22/2024 |
Work Description | Not set |
Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
Sample Taken Date | 06/01/2022 | Sample Unique Key | 29 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/08/2022 |
Sample type | Acceptance | A brief description of the sample | 3/4" HMA-SP PG64-16 |
The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
First name of sampler or witnessed by | Jim | Last name of sampler or witnessed by | Carnell |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Perkins | Transportation Laboratory (TL) Number | 059346 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 3 | Tank number | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-06-01-29
DIME Test ID: 2022-06-01-29-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-06-22
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/14/2022
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.162 kPa
Phase Angle (δ) (for the 10 cycles): 86.7 degree
Complex Modulus (G*) (for the 10 measurements): 1.346 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.35 kPa
General comments (publicly viewable) (Max 1000 characters): ORIG
Test was verified on 6/22/2022 ✔