Summary for Test 2022-05-26-27-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 215364
DEA: 07333204
EFIS: 0716000301
DIST-CO-RTE-PM07-LA-5-.8/.8
Award Date09/08/2021
Closeout Date03/01/2023
Work DescriptionINSTALL SOLAR PV POWERED LIGHTING SYSTEM.
Location DescriptionIN KERN COUNTY NEAR LEBEC AT VARIOUS LOCATIONS FROM OFF-RAMP OF NORTHBOUND REST AREA TO 0.1 MILE NORTH OF OFF-RAMP OF SOUTHBOUND REST AREA.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date05/26/2022 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/26/2022
Sample typeAcceptance A brief description of the sampleAggregate Base
The quantity of what the sample constitutes102 yd2 From where was the sample collectedJob Site
First name of sampler or witnessed byRosauro Last name of sampler or witnessed byNogoy
Title of samplerTEC Telephone number of sampler2137939321
Laboratory sample identification22-1278 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sampleAggregate Base A detailed description of where the material sample was collectedFrom various locations at Aggregate Base
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-05-26-27
DIME Test ID: 2022-05-26-27-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-06-01

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Rosauro Nogoy
Date of test: 05/26/2022
Gage No.: 60202
Test No.: 1
Nuclear By: Rosauro Nogoy
Non-Bias Plan No.: 2
Depth: 12 in
Material No.: Imported Material
Material Type: Aggregate Base
Impact By: Rosauro Nogoy
Standard Count Density: 2376 g/cc
Count or Density 1: 2.37 g/cc
Count or Density 2: 2.39 g/cc
Count or Density 3: 2.39 g/cc
Standard Count Moisture: 618 g/cc
Moisture Count 1: 0.08 g/cc
Moisture Count 2: 0.11 g/cc
Moisture Count 3: 0.1 g/cc
Sum of Count or Density: 7.15 g/cc
Average of Count or Density: 2.38 g/cc
Sum of Moisture Count: 0.29 g/cc
Average of Moisture Count: 0.10 g/cc
Calculated Percent Relative Compaction: 98.5 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/1/2022