Summary for Test 2022-05-12-31-1

Test performed: AASHTO T59-16

Project Information

Project IdentifiersProject ID: 993427
DEA: 061C4004
EFIS: 0621000165
DIST-CO-RTE-PM06-TUL-198,245-37.5/41.3,6.0/8.1
Award Date01/28/2022
Closeout Date10/03/2022
Work DescriptionCOLD PLANE AC PAVEMENT, HMA (TYPE A), SLURRY SEAL, AND STRIPING.
Location DescriptionTULARE COUNTY NEAR THREE RIVERS ON ROUTE 198 FROM 0.3 MILE EAST OF THREE RIVERS DRIVE TO ROAD TO SAINT ANTHONY AND IN WOODLAKE ON ROUTE 245 FROM SAINT JOHNS RIVER TO CAJON AVENUE
QA Service Level1 (Verified on 12/06/2021)

Sample Information

Sample Taken Date05/12/2022 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/16/2022
Sample typeAcceptance A brief description of the sampleEMULSION
The quantity of what the sample constitutes1 OF 2 BOTTLES From where was the sample collectedJob Site
First name of sampler or witnessed bySEAN Last name of sampler or witnessed byH
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVSS Emultech Transportation Laboratory (TL) NumberC039875
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradePMCQS-1h
Lot NumberNot set Sub LotNot set

Test Details

DIME Sample ID: 2022-05-12-31
DIME Test ID: 2022-05-12-31-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2022-05-17

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 05/17/2022
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 457.6 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 425.2 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 454.1 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 421.9 g
Beaker 1 Residue: 64.8 %
Beaker 2 Residue: 64.4 %
Percentage of residue: 65.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/17/2022