Summary for Test 2022-04-19-46-3

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 214402
DEA: 010E7704
EFIS: 0115000009
DIST-CO-RTE-PM01-HUM-101-R17.9/87.8
Award Date01/21/2020
Closeout Date07/21/2023
Work DescriptionSTRENGTHEN 2 BRIDGES.
Location DescriptionHUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
QA Service Level1 (Verified on 09/16/2019)

Sample Information

Sample Taken Date04/19/2022 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/26/2022
Sample typeQuality Assurance A brief description of the sampleA449 Bolt/nut/Washer
The quantity of what the sample constitutes29 From where was the sample collectedManufacturer
First name of sampler or witnessed byDane Last name of sampler or witnessed bymckinnon
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePortland Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)5392477 Nut Mfg. Lot Number(s)446165A
Washer Mfg. Lot Number(s)19461 Bolt SpecificationA449
Bolt Length(s)14" Nut SpecificationA563
Washer SpecificationF436 Finishhdg
Diameter/Size1" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2022-04-19-46
DIME Test ID: 2022-04-19-46-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2022-05-17

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 05/16/2022
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B94965Nut Proof Load

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 5/17/2022