Summary for Test 2016-06-06-4-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 210698 DEA: 11299204 EFIS: 1100000422 |
---|---|
DIST-CO-RTE-PM | 11-SD-94,805-Var |
Award Date | 10/13/2015 |
Closeout Date | 09/10/2018 |
Work Description | SEISMIC RETROFIT 4 BRIDGES ON ROUTES 94 AND 805. |
Location Description | IN SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 01/13/2016) |
Sample Information
Sample Taken Date | 06/06/2016 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/08/2016 |
Sample type | Quality Assurance | A brief description of the sample | Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Source |
First name of sampler or witnessed by | Hamid | Last name of sampler or witnessed by | Akbarzadegan |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Pacific Steel | Transportation Laboratory (TL) Number | C958028 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #9 | Coupler Model | 500-510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Nucor |
Coupler Component Heat/Lot Number(s) | 0K1753, 75061855 | Rebar Heat Number(s) | PL16201548, PL16101523 |
Rebar Size 2 | NA | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2016-06-06-4
DIME Test ID: 2016-06-06-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-06-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 06/09/2016
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | NA | #9/29mm | 1 | -0.0029 | 96148 | 96148 | Bar Broke,Ok Necking |
General comments (publicly viewable) (Max 1000 characters): Bar Broke,Ok Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/9/2016 ✔