Summary for Test 2022-03-31-26-1

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 215236
DEA: 081C6804
EFIS: 0812000343
DIST-CO-RTE-PM08-RIV-74,79and371-Varies
Award Date12/29/2020
Closeout DateNot set
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE, RETAINING WALL AND BOX CULVERT.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/02/2021)

Sample Information

Sample Taken Date03/31/2022 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2022
Sample typeQuality Control A brief description of the sampleCIP Concrete
The quantity of what the sample constitutes2 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byRodrigo Last name of sampler or witnessed byLupian
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Temecula Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1610974
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected30164745
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedLocation 3 - Arroyo Seco Stage 2 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-03-31-26
DIME Test ID: 2022-03-31-26-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-04-28

Test Results


Number of specimens: 2
Input Type: Calculated
Tester's full name: Javier Lopez
Date of test: 04/28/2022
Correction factor: 0
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): no data
Break Description of Cylinder 2 (if not 'cone'): no data
Average Compressive Strength (to nearest 10): 5360 lb/in^2
Compressive Strength of Cylinder 1: 5393 lb/in^2
Compressive Strength of Cylinder 2: 5331 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/28/2022