Summary for Test 2022-03-10-43-1
Test performed: CONCLP 2-16Project Information
Project Identifiers | Project ID: 993154 DEA: 120R3404 EFIS: 1218000079 |
---|---|
DIST-CO-RTE-PM | 12-ORA-73-12.9/R26.8 |
Award Date | 09/16/2021 |
Closeout Date | 09/28/2023 |
Work Description | REPLACE APPROACH SLABS, JOINT SEAL, AND APPLY METHACRYLATE ON BRIDGES. |
Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS FROM MOULTON PARKWAY UNDERCROSSING IN LAGUNA NIGUEL TO BRISTOL STREET UNDERCROSSING IN COSTA MESA |
QA Service Level | 1 (Verified on 08/02/2021) |
Sample Information
Sample Taken Date | 03/10/2022 | Sample Unique Key | 43 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/17/2022 |
Sample type | Quality Assurance | A brief description of the sample | rapid set patching |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Thao | Last name of sampler or witnessed by | Vu |
Title of sampler | Quality Manager | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sika Corporation | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Rapid Set | Manufacturer | Sika Corporation |
---|---|---|---|
Mix no. | 3623 | Materials Received | Sikaquick 2500 |
Lot no. | 3006137693 | Batch no. | 03092202 |
Test Details
DIME Sample ID: 2022-03-10-43
DIME Test ID: 2022-03-10-43-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 2-16: Rapid Set Patching Materials
Test Release Date: 2022-04-22
Test Results
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 04/22/2022
Compressive Strength @ 3 hrs (CTM 551): 5210
Compressive Strength @ 24 hrs (CTM 551): 5890
Flexure Strength @ 24 hrs (CTM 551): 0
Bond Strength @ 24 hrs - SSD (CTM 551): 0
Bond Strength @ 24 hrs - Dry (CTM 551): 0
Water Absorption (CTM 551): 0
Abrasion @ 24 hrs (CTM 550): 24
Drying Shrinkage @ 4 days (CTM 596): 0
Soluble Chlorides (CTM 422): 0
Water Soluble-Sulfates (CTM 417): 0
Material Weight: 50
Water Weight: 5.74
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/22/2022 ✔