Summary for Test 2022-03-29-4-2
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/29/2022 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2022 |
Sample type | Quality Assurance | A brief description of the sample | 1X5 A325 HDG |
The quantity of what the sample constitutes | 300 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Chad | Last name of sampler or witnessed by | Duckworth |
Title of sampler | Quality Assurance Manager | Telephone number of sampler | 19403682512 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Fontana Fasteners | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 10711210 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | a325 | |
Bolt Length(s) | 5" | Nut Specification | dh |
Washer Specification | f436 | Finish | hdg |
Diameter/Size | 1" | Bolt Mfg. Lot Number | l388x1 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2022-03-29-4
DIME Test ID: 2022-03-29-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2022-05-05
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 04/18/2022
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1B | L386X1 | 1.0000 | 94632 | 420.94 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 5/5/2022 ✔