Summary for Test 2022-01-13-43-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date01/13/2022 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing01/15/2022
Sample typeQuality Assurance A brief description of the sample1 x 4 PCC Aggregate
The quantity of what the sample constitutes300 CYS From where was the sample collectedFabricator
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byZubieta
Title of samplerTransportation Engineer Telephone number of sampler2137924795
Laboratory sample identification5591 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFlat Iron Portable @ 210 & Paxton Transportation Laboratory (TL) NumberC-924030
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0023
The fabricator's/manufacturer's product name for the sampleJPCP The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt at Plant
Where the material sample would have been placed if not sampledPCC SLAB Primary Aggregate Nominal Size1 inch
The concrete mix design numberJPCP-3215-06 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-13-43
DIME Test ID: 2022-01-13-43-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-04-12

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Gerardo Zubieta
Date of test: 01/13/2022
Cumulative Mass RetainedCumulative Percent Passing
9754 grams
0 grams100 %
1132 grams88 %
6154 grams37 %
9309 grams5 %
9483 grams3 %
9519 grams2 %
9539 grams2 %
9754 grams
General comments (publicly viewable) (Max 1000 characters): Retested 3/4" screen with 2nd bag sampled and aggregate complied with specified range.

Test was verified on 4/12/2022