Summary for Test 2022-01-06-58-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date01/06/2022 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/06/2022
Sample typeQuality Assurance A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes300 CYS From where was the sample collectedFabricator
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byZubieta
Title of samplerTransportation Engineer Telephone number of sampler2137924795
Laboratory sample identification5555 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFlat Iron Portable @ 210 & Paxton Transportation Laboratory (TL) Number924023
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0023
The fabricator's/manufacturer's product name for the sampleJPCP The fabricator/manufacturer designation for the samplePortable Plant
The plant numberFlat Iron Portable A detailed description of where the material sample was collectedstock pile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design numberFWI 3018-A1 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-06-58
DIME Test ID: 2022-01-06-58-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-04-11

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: Gerardo Zubieta
Date of test: 01/06/2022
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.9
Sand reading (test 1): 4.6
Clay reading (test 2): 4.8
Sand reading (test 2): 4.4
Sand equivalent (test 1): 94
Sand equivalent (test 2): 92
Sand equivalent before temperature correction: 92
Sand equivalent after temperature correction: 92
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/11/2022