Summary for Test 2022-02-02-52-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date02/02/2022 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/03/2022
Sample typeVerification A brief description of the sample1/2" HMA- A
The quantity of what the sample constitutes12 boxes of 1/2" HMA From where was the sample collectedManufacturer
First name of sampler or witnessed byTeichert Last name of sampler or witnessed byPersonnel
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Perkins GenCor Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2022-02-02-52
DIME Test ID: 2022-02-02-52-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2022-04-07

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 02/11/2022
Percent Air Voids: 4.7 %
Percent Air Voids 2: 4.4 %
Percent Air Voids 3: 4.5 %
Percent Air Voids Average: 4.5 %
General comments (publicly viewable) (Max 1000 characters): JMF 22-003

Test was verified on 4/7/2022