Summary for Test 2022-03-17-37-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/17/2022 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/17/2022 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | WCS PCC Aggregate |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Albert | Last name of sampler or witnessed by | Segura |
Title of sampler | Quality Control Supervisor | Telephone number of sampler | 9094368680 |
Laboratory sample identification | Cemex Moorpark WCS | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Cemex Moorpark | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-56-0014 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Cemex Moorpark WCS | The fabricator/manufacturer designation for the sample | WCS |
The plant number | 4425 | A detailed description of where the material sample was collected | Production stockpile |
Where the material sample would have been placed if not sampled | Ready Mix Concrete | Primary Aggregate Nominal Size | fine |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Combined Gradation Report Information
Combined Gradation Report Id | Bin Index | Dime Test Id |
---|---|---|
No assigned tests for this sample. |
Test Details
DIME Sample ID: 2022-03-17-37
DIME Test ID: 2022-03-17-37-2
Testing Lab: CEMEX - Central & Southern California
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-04-04
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Albert Marc Segura
Date of test: 03/30/2022
Temperature correction: 70
Temperature of solution: 70
Clay reading (test 1): 45
Sand reading (test 1): 38
Clay reading (test 2): 44
Sand reading (test 2): 38
Sand equivalent (test 1): 85
Sand equivalent (test 2): 87
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters): Testing Conducted @ Twining Labs Long Beach
Test was verified on 4/4/2022 ✔