Summary for Test 2016-05-19-2-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210244
DEA: 05492804
EFIS: 0500000576
DIST-CO-RTE-PM05-SLO-1-64.0/R66.9
Award Date05/27/2015
Closeout Date03/06/2019
Work DescriptionCONSTRUCT BRIDGES AND REALIGN TWO LANE HIGHWAY.
Location DescriptionSAN LUIS OBISPO COUNTY ABOUT 9 MILES NORTH OF SAN SIMEON FROM PIEDRAS BLANCAS LIGHTHOUSE ROAD TO ARROYO DE LA CRUZ BRIDGE
QA Service Level1 (Verified on 06/23/2015)

Sample Information

Sample Taken Date05/19/2016 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/20/2016
Sample typeQuality Assurance A brief description of the sampleCoupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byDominic Last name of sampler or witnessed by Rabay
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau, HRC Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size#11 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)75061855, 58023784 Rebar Heat Number(s)5802378403
Rebar Size 2 #11 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-05-19-2
DIME Test ID: 2016-05-19-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-05-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/20/2016
UTM: 2000KIP
Halo ID: N/A
Temperature: 70 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
112#11/36mm1.56-0.005214694894197necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 5/23/2016