Summary for Test 2022-03-03-33-4
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 211260 DEA: 072159U4 EFIS: 0715000160 |
---|---|
DIST-CO-RTE-PM | 07-LA,ORA-5-0.0/1.5, 44.3/44.4 |
Award Date | 05/27/2016 |
Closeout Date | 08/01/2023 |
Work Description | CONSTRUCT HOV LANES AND MIX FLOW LANES. |
Location Description | LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK |
QA Service Level | 1 (Verified on 03/16/2016) |
Sample Information
Sample Taken Date | 03/03/2022 | Sample Unique Key | 33 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/08/2022 |
Sample type | Department Acceptance | A brief description of the sample | 1x4 pcc aggregate |
The quantity of what the sample constitutes | 80 cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | 2137924794 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | SECURITY PAVING - LA MIRADA | Transportation Laboratory (TL) Number | c-0303A1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 6031 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | PCC mix | The fabricator/manufacturer designation for the sample | mix G3-15-STR-002 |
The plant number | A detailed description of where the material sample was collected | Conveyer Belt | |
Where the material sample would have been placed if not sampled | Roadway | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | G3-15-STR-002 | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-03-33
DIME Test ID: 2022-03-03-33-4
Testing Lab: CT D07 - Plant Services
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2022-03-25
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: M Tarafder
Date of test: 03/09/2022
Top sediment column reading (single primary size): 0.4 in
Cleanness value (single primary size): 89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/25/2022 ✔