Summary for Test 2022-02-01-25-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 993154 DEA: 120R3404 EFIS: 1218000079 |
---|---|
DIST-CO-RTE-PM | 12-ORA-73-12.9/R26.8 |
Award Date | 09/16/2021 |
Closeout Date | 09/28/2023 |
Work Description | REPLACE APPROACH SLABS, JOINT SEAL, AND APPLY METHACRYLATE ON BRIDGES. |
Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS FROM MOULTON PARKWAY UNDERCROSSING IN LAGUNA NIGUEL TO BRISTOL STREET UNDERCROSSING IN COSTA MESA |
QA Service Level | 1 (Verified on 08/02/2021) |
Sample Information
Sample Taken Date | 02/01/2022 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/01/2022 |
Sample type | Quality Control | A brief description of the sample | 2 pints 204,chp,zcure,8020 |
The quantity of what the sample constitutes | 25000 gallons | From where was the sample collected | Source |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Tikusis |
Title of sampler | Technical Director | Telephone number of sampler | 17073309227 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Kwik Bond Polymers | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 2210091190 |
---|---|---|---|
Batch number | 2210091190 | Mix number | 2210091190 |
Test Details
DIME Sample ID: 2022-02-01-25
DIME Test ID: 2022-02-01-25-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2022-03-16
Test Results
Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 03/04/2022
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 21.6
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.10
Volatile content (ASTM D 2369) 30% max: 27.5
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 844.3
Tack free time, 400 minutes max: 270
General comments (publicly viewable) (Max 1000 characters): Bond strength and Tack free accepted based on supplier's results.
Test was verified on 3/16/2022 ✔