Summary for Test 2022-02-15-20-1
Test performed: CONCLP 2-16Project Information
Project Identifiers | Project ID: 99999 DEA: 0322222 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 02/15/2022 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/15/2022 |
Sample type | Quality Assurance | A brief description of the sample | rapid set patching |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jim | Last name of sampler or witnessed by | Bluse |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sika Corporation | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Rapid Set | Manufacturer | Sika Corporation |
---|---|---|---|
Mix no. | 3607 | Materials Received | Sikaquick 2500 |
Lot no. | 38861119200B-59 | Batch no. | 38861119200B-59 |
Test Details
DIME Sample ID: 2022-02-15-20
DIME Test ID: 2022-02-15-20-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 2-16: Rapid Set Patching Materials
Test Release Date: 2022-03-15
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 03/15/2022
Compressive Strength @ 3 hrs (CTM 551): 3920
Compressive Strength @ 24 hrs (CTM 551): 7300
Flexure Strength @ 24 hrs (CTM 551): 881
Bond Strength @ 24 hrs - SSD (CTM 551): 466
Bond Strength @ 24 hrs - Dry (CTM 551): 547
Water Absorption (CTM 551): 6
Abrasion @ 24 hrs (CTM 550): 21
Drying Shrinkage @ 4 days (CTM 596): 0.005
Soluble Chlorides (CTM 422): 0.00065
Water Soluble-Sulfates (CTM 417): 0.0442
Material Weight: 50
Water Weight: 5.74
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/15/2022 ✔