Summary for Test 2022-03-03-20-1

Test performed: ASTM C117-17

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date03/03/2022 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/01/2022
Sample typeQuality Control A brief description of the samplesand
The quantity of what the sample constitutes305 From where was the sample collectedJob Site
First name of sampler or witnessed byRoberto Last name of sampler or witnessed byReyes
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namevulcan materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SMARA 91 15 0041
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedsilo
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-03-03-20
DIME Test ID: 2022-03-03-20-1
Testing Lab: Con-Fab California, LLC
Test Method: ASTM C117-17: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Test Release Date: 2022-03-11

Test Results


Input Type: Calculated
Tester's full name: Roberto Reyes
Date of test: 03/03/2022
The method used?: Procedure A
Percent finer than No. 200 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/11/2022