Summary for Test 2022-02-08-44-3
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 215221 DEA: 07332604 EFIS: 0716000287 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-R12.4/14.9 |
| Award Date | 12/16/2020 |
| Closeout Date | 11/25/2024 |
| Work Description | REMOVE RAISED ISLAND, CONSTRUCT CONCRETE BARRIER AND INSTALL LIGHTING. |
| Location Description | THE COUNTY AND CITY OF LOS ANGELES FROM 0.1 MILE EAST OF ARLINGTON AVENUE OVERCROSSING TO 0.7 MILE EAST OF ROUTE 10/110 SEPARATION |
| QA Service Level | 1 (Verified on 03/19/2021) |
Sample Information
| Sample Taken Date | 02/08/2022 | Sample Unique Key | 44 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2022 |
| Sample type | Department Acceptance | A brief description of the sample | 1x4 aggregate |
| The quantity of what the sample constitutes | 30 CY | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
| Title of sampler | Telephone number of sampler | 2137924794 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Robertsons gardena | Transportation Laboratory (TL) Number | C0208A1 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 5846 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0008::CABAZON QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | PCC mix | The fabricator/manufacturer designation for the sample | mix SC675B39 |
| The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
| Where the material sample would have been placed if not sampled | WB 10 Off Ramp | Primary Aggregate Nominal Size | 1 inch |
| The concrete mix design number | SC675B39 | Lot number | |
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-08-44
DIME Test ID: 2022-02-08-44-3
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-03-11
Test Results
What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: A.Behjati
Date of test: 02/15/2022
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1140 grams | ||||||
| 36.0 grams | 97 % | |||||
| 92.0 grams | 92 % | |||||
| 746.0 grams | 35 % | |||||
| 1011.0 grams | 11 % | |||||
| 1140.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/11/2022 ✔