Summary for Test 2022-01-28-8-3

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 215255
DEA: 040A7714
EFIS: 0420000287
DIST-CO-RTE-PM04-ALA-80-6.4-6.6
Award Date05/03/2021
Closeout Date12/01/2023
Work DescriptionCONSTRUCT PEDESTRIAN OVERCROSSING BRIDGE AND RETAINING WALLS. GILMAN INTERCHANGE IMPROVEMENTS
Location DescriptionALAMEDA COUNTY IN BERKELEY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.1 MILE SOUTH OF GILMAN STREET UNDERCROSSING
QA Service Level1 (Verified on 12/07/2020)

Sample Information

Sample Taken Date01/28/2022 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/02/2022
Sample typeVerification A brief description of the sampleASTM A706 HRC 220 full size T heads
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of sampler Telephone number of sampler7073428602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Fountain Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-009-22 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)1066917 Head Manufacturer Lot Number(s)308313
Rebar Size#14 Headed Bar Model Name HRC 220
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeCircular Rebar ManufacturerCMC Etiwanda
Head ManufacturerBerkeley Forge and Tool Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2022-01-28-8
DIME Test ID: 2022-01-28-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2022-02-04

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 02/03/2022
UTM: 2000kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
112.25211788.8694128Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 2/4/2022