Summary for Test 2021-06-14-43-8
Test performed: AASHTO T335-09r13Project Information
Project Identifiers | Project ID: 215250 DEA: 021J4404 EFIS: 0220000079 |
---|---|
DIST-CO-RTE-PM | 02-MOD-299-20.0/23.1,23.5/24.5,33.5/37.5 |
Award Date | 12/14/2020 |
Closeout Date | 09/27/2021 |
Work Description | ASPHALT RUBBER CHIP SEAL. |
Location Description | MODOC COUNTY AT VARIOUS LOCATIONS FROM 1.8 MILES WEST OF ROUTE 139 TO 0.3 MILE WEST OF RATTLESNAKE CREEK BRIDGE |
QA Service Level | 1 (Verified on 10/30/2020) |
Sample Information
Sample Taken Date | 06/14/2021 | Sample Unique Key | 43 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/22/2021 |
Sample type | Department Acceptance | A brief description of the sample | 1 bag of Uncoated 3/8″ Aggregate for use in ARB Chip Seal |
The quantity of what the sample constitutes | 1/2 day to whole project | From where was the sample collected | Other |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D78852 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Eagle Peak Rock and Paving, Alturas, CA | Transportation Laboratory (TL) Number | 853350 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Eagle Peak |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Unknown |
Where the material sample would have been placed if not sampled | 02 MOD 299 | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Not Applicable | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-14-43
DIME Test ID: 2021-06-14-43-8
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2022-01-28
Test Results
Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 06/23/2021
Percentage of fractured, coarse, 2 faced particles tested: 100 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/28/2022 ✔