Summary for Test 2021-06-21-18-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 215251
DEA: 021J4604
EFIS: 0220000081
DIST-CO-RTE-PM02-SIS-96-34.5/38.8,88.0/92.0
Award Date02/02/2021
Closeout Date09/27/2021
Work DescriptionHMA OVERLAY, REPLACE AC SURFACING, SHOULDER BACKING & TRAFFIC STRIPE.
Location DescriptionSISKIYOU COUNTY NEAR HAPPY CAMP FROM 0.1 MILE EAST OF OAK FLAT CREEK BRIDGE TO 0.1 MILE EAST OF BENJAMIN CREEK ROAD AND FROM 0.3 MILE WEST OF BEAVER CREEK BRIDGE TO 1.0 MILE WEST OF LUMGREY CREEK BRIDGE
QA Service Level1 (Verified on 10/30/2020)

Sample Information

Sample Taken Date06/21/2021 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2021
Sample typeAcceptance A brief description of the sample1 bag of Fine RAP (No. 4) for use in 3/8-inch Type HMA
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byDevin Last name of sampler or witnessed byOwens
Title of samplerPEI Telephone number of sampler
Laboratory sample identificationD78848B Linked DIME Sample ID2021-06-21-17
The fabricator/manufacturer/facility nameTullis - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number853076
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier
Structure nameNot Applicable

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceNorthstate Asphalt
Aggregate SizeFine Aggregate SourceUnknown
RAP Stockpile Stockpile Size (tons)Unknown
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-21-18
DIME Test ID: 2021-06-21-18-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-01-21

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 06/22/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.6 grams
Mass of oven-dry sample in air for Sample 1: 1290.4 grams
Mass of container filled with the sample and water for Sample 1: 8111.1 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.501
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): Insufficient specimen size. Gser ≈ 2.750

Test was verified on 1/21/2022