Summary for Test 2022-01-04-5-3

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Award Date04/21/2020
Closeout DateNot set
Work DescriptionPanther Creek & Hunter Creek Bridges
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date01/04/2022 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/10/2022
Sample typeQuality Assurance A brief description of the sampleAnchor Rod Assembly
The quantity of what the sample constitutes16 From where was the sample collectedFabricator
First name of sampler or witnessed byCharles Last name of sampler or witnessed byFranco
Title of samplerQA Inspector Telephone number of sampler8585839270
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameThompson Metal Fab Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)120203173860 Rod, 100105020 Top Nut, 3500018274 Washer RD, A1F050 PL Washer, B20010418 Nut Nut Mfg. Lot Number(s)446165B DOM, HY2044034HVG IMP
Washer Mfg. Lot Number(s)PL 3500018274 RD Bolt SpecificationASTM F1554 GR 36 ATR
Bolt Length(s)43" Nut SpecificationASTM A563 GR DH DOM ASTM A563 GR A IMP
Washer SpecificationASTM A572 GR 50 SQ PL ASTM A572 GR 50 RD PL FinishHDG
Diameter/Size1" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2022-01-04-5
DIME Test ID: 2022-01-04-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2022-01-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 01/19/2022
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A446165B94444Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 1/19/2022