Summary for Test 2016-02-10-5-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209795
DEA: 08383504
EFIS: 0800000638
DIST-CO-RTE-PM08-RIV-74-63.0
Award Date10/10/2014
Closeout Date08/29/2017
Work DescriptionREPLACE HURKEY CREEK BRIDGE
Location DescriptionRIVERSIDE COUNTY NEAR IDYLLWILD AT HURKEY CREEK BRIDGE
QA Service Level1 (Verified on 09/12/2014)

Sample Information

Sample Taken Date02/10/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/12/2016
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders 6 x 12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byArnel Last name of sampler or witnessed byVega
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification915-5E Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRobertsons Transportation Laboratory (TL) NumberA1B2C3D4E5
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberRRM 09014
The truck number from where the sample was collected1586 The batch plant ticket number from where the sample was collected1217098
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedBACK OF THE TRUCK Where the material sample would have been placed if not sampledNW RETAINING WALL STEM
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-02-10-5
DIME Test ID: 2016-02-10-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-03-09

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 03/09/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 127050 lb
Maximum load on cylinder 2: 136210 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4478.3 psi
Compressive strength of cylinder 2: 4801.2 psi
Compressive strength (to nearest 10 psi): 4640 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/9/2016