Summary for Test 2021-04-29-32-6

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 214355
DEA: 120K0214
EFIS: 1214000096
DIST-CO-RTE-PM12-ORA-5-12.4/14.5
Award Date12/20/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY
Location DescriptionORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING
QA Service Level1 (Verified on 10/31/2019)

Sample Information

Sample Taken Date04/29/2021 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/30/2021
Sample typeQuality Control A brief description of the sample6x12 Cylinders
The quantity of what the sample constitutes33.6 CY From where was the sample collectedFabricator
First name of sampler or witnessed byAugusto Last name of sampler or witnessed byRios, Jr.
Title of samplerQC Insptector Telephone number of sampler
Laboratory sample identification429 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCoreslab Structures L A Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number212
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected78540 - 78542
Concrete batch plant The fabricator/manufacturer designation for the sample138
A detailed description of where the material sample was collectedBed 9 from front discharge RMT into wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-04-29-32
DIME Test ID: 2021-04-29-32-6
Testing Lab: Coreslab
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-12-09

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Francisco Lopez
Date of test: 05/06/2021
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 228420 lb
Maximum load on cylinder 2: 237726 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.2 in^2
Cross sectional area of cylinder 2: 28.2 in^2
Compressive strength (to nearest 10 psi): 8270 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/9/2021