Summary for Test 2021-11-08-42-4
Test performed: AASHTO T51-13Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/08/2021 | Sample Unique Key | 42 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/08/2021 |
Sample type | Quality Control | A brief description of the sample | PG58-16 Asphalt binder |
The quantity of what the sample constitutes | 1 of 2 cans | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Partenan |
Title of sampler | Sr Asphalt Technician | Telephone number of sampler | 6614327352 |
Laboratory sample identification | 5816211108 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | San Joaquin Refinery | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
---|---|---|---|
Modified | No | Lot number | 5816211108 |
Sublot number | Tank number | 2002 | |
Time of sample | 9:15am | HMA Supplier | |
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-08-42
DIME Test ID: 2021-11-08-42-4
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-12-03
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Calculated
Tester's full name: Don Conner
Date of test: 11/08/2021
Ductility of test #1 (D1): 150 cm
Ductility of test #2 (D2): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): Test @ 25C
Test was verified on 12/3/2021 ✔