Summary for Test 2021-11-05-25-2
Test performed: AASHTO T84-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/05/2021 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/22/2021 |
Sample type | Verification | A brief description of the sample | 1/2" HMA WMA PG 64-10 with 15% RAP |
The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Jay | Last name of sampler or witnessed by | Horton |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 21-JMF-0207 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Granite Santa Clara Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0002::VERNALIS |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-05-25
DIME Test ID: 2021-11-05-25-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-12-02
Test Results
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 12/02/2021
Mass of saturated surface dry sample (before pycnometer) (S): 501.1 grams
Mass of the pycnometer with water and aggregate (C): 984.2 grams
Mass of the pycnometer with water (B): 675.4 grams
Mass of the oven dried sample (before pycnometer) (A): 489.7 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 501.1 grams
Mass of the oven dry aggregate (for absorption) (A): 489.7 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.547
Bulk specific gravity (SSD Basis): 2.606
Apparent specific gravity: 2.707
Absorption: 2.3 %
General comments (publicly viewable) (Max 1000 characters): Bulk specific gravity (SSD) of fine aggregate - Bulk specific gravity of fine aggregate - Bulk specific gravity of fine aggregate - Apparent specific gravity of supplemental fines - Absorption of fine aggregate.
Test was verified on 12/2/2021 ✔