Summary for Test 2016-01-28-3-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout DateNot set
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Sample Information

Sample Taken Date01/28/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/04/2016
Sample typeQuality Assurance A brief description of the sampleTwo concrete cylinders
The quantity of what the sample constitutes45 From where was the sample collectedJob Site
First name of sampler or witnessed byChetan Last name of sampler or witnessed bySihra
Title of samplerTED Telephone number of sampler415-823-6360
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCentral Concrete Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameRetaining Wall 8

Material Information

Material TypeConcrete The concrete mix design numberD101C5E1
The truck number from where the sample was collected170 The batch plant ticket number from where the sample was collected18161269
Concrete batch plant30 The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedConcrete Pump Where the material sample would have been placed if not sampledRetaining 8
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-01-28-3
DIME Test ID: 2016-01-28-3-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-02-25

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM TTO
Date of test: 02/25/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 143227 lb
Maximum load on cylinder 2: 138734 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 5098.9 psi
Compressive strength of cylinder 2: 4923.1 psi
Compressive strength (to nearest 10 psi): 5010 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 2/25/2016