Summary for Test 2021-11-02-23-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 214114
DEA: 040A5394
EFIS: 0418000244
DIST-CO-RTE-PM04-SOL-80,12-11.4/12.8, 2.1/2.8
Award DateNot set
Closeout Date02/24/2023
Work DescriptionWiden EB SR-12 Connector, Construct 3 ramps & 2 box girder bridges, remove existing bridge, etc.
Location DescriptionI-80/I-680/Route 12 Interchange
QA Service Level1 (Verified on 04/23/2019)

Sample Information

Sample Taken Date11/02/2021 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/15/2021
Sample typeQuality Assurance A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes3 Cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byGamal Last name of sampler or witnessed byAbushaban
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMCM Transportation Laboratory (TL) Number051707
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier23-0258G
Structure nameDeck Pour 1

Material Information

Material TypeConcrete The concrete mix design number1619340
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedChute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-11-02-23
DIME Test ID: 2021-11-02-23-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-11-30

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 11/30/2021
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.02 in
Maximum load on cylinder 1: 97195 lb
Maximum load on cylinder 2: 91610 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): Specimen 1 broke out of range of pair and thus was excluded from average.
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Compressive strength of cylinder 1: 7695.6 psi
Compressive strength of cylinder 2: 7219.1 psi
Compressive strength (to nearest 10 psi): 7460 psi
General comments (publicly viewable) (Max 1000 characters): Specimen 1 broke out of range of pair and thus was excluded from average.

Test was verified on 11/30/2021