Summary for Test 2021-11-09-26-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 215587
DEA: 081L6804
EFIS: 0820000138
DIST-CO-RTE-PM08-RIV-91,15-7.5/13.4,8.2/23.9
Award Date04/30/2021
Closeout Date08/16/2023
Work DescriptionSLAB REPLACEMENT, PLACE SLURRY SEAL AND REPLACE AC SURFACING.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR CORONA AND MURRIETA ON ROUTE 91 FROM ROUTE 15/91 SEPARATION TO 0.4 MILE EAST OF TYLER STREET AND ON ROUTE 15 FROM 1.5 MILES NORTH OF WINCHESTER ROAD TO NICHOLS ROAD
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date11/09/2021 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/10/2021
Sample typeAcceptance A brief description of the sampleAC Drum Aggregate
The quantity of what the sample constitutes1 bag combined aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byIdris Last name of sampler or witnessed byNajjar
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedbelt an chute
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number103793 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-09-26
DIME Test ID: 2021-11-09-26-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-11-24

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: A. Nguyen
Date of test: 11/15/2021
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 97 %
Cumulative percent passing the 1/2 in. sieve: 85 %
Cumulative percent passing the 3/8 in. sieve: 72 %
Cumulative percent passing the #4 sieve: 48 %
Cumulative percent passing the #8 sieve: 29 %
Cumulative percent passing the #16 sieve: 19 %
Cumulative percent passing the #30 sieve: 12 %
Cumulative percent passing the #50 sieve: 7 %
Cumulative percent passing the #100 sieve: 5 %
Cumulative percent passing the #200 sieve: 3.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/24/2021