Summary for Test 2021-11-04-22-8

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 215182
DEA: 08476424
EFIS: 0816000186
DIST-CO-RTE-PM08-SBD-215,259-4.0/17.8,0.0/1.5
Award DateNot set
Closeout Date01/23/2023
Work DescriptionINSTALL FIBER OPTIC CABLE SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR SAN BERNARDINO ON ROUTE 215 FROM ROUTE 215/10 SEPARATION TO ROUTE 215/15 SEPARATION AND ON ROUTE 259 FROM ROUTE 259/215 SEPARATION TO ROUTE 259/210 SEPARATION
QA Service Level1 (Verified on 01/20/2021)

Sample Information

Sample Taken Date11/04/2021 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/08/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP, 0.5% LAS
The quantity of what the sample constitutes4 Bags of Aggregate, 4 Bags of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Corona Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0621A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0073, 91-33-0027
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number224112 CORD SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-04-22
DIME Test ID: 2021-11-04-22-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2021-11-23

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Michael Magana
Date of test: 11/12/2021
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %
General comments (publicly viewable) (Max 1000 characters):