Summary for Test 2021-11-04-7-22

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 214402
DEA: 010E7704
EFIS: 0115000009
DIST-CO-RTE-PM01-HUM-101-R17.9/87.8
Award Date01/21/2020
Closeout Date07/21/2023
Work DescriptionSTRENGTHEN 2 BRIDGES.
Location DescriptionHUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
QA Service Level1 (Verified on 09/16/2019)

Sample Information

Sample Taken Date11/04/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/04/2021
Sample typeQuality Assurance A brief description of the sample3/4-10x21/2F3125A325
The quantity of what the sample constitutes683 From where was the sample collectedFabricator
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerCT METS QA INSPECTOR Telephone number of sampler916-826-6371
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCK Johnson Industries Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB22-114-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)19954
Heat Number(s) Nut Mfg. Lot Number(s)448953B
Washer Mfg. Lot Number(s)E0573 Bolt SpecificationASTM A325
Bolt Length(s)2 1/2" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishHDG
Diameter/Size3/4-10x21/2 Bolt Mfg. Lot NumberE005B1
Rocap Test Requirement(s)Yes Lubricant Requirements(s)No

Test Details

DIME Sample ID: 2021-11-04-7
DIME Test ID: 2021-11-04-7-22
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-11-18

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 11/17/2021
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: E0573
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: P F436
Size: .75 in
Bolt Length: no data
Measurement Average: 2.19 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2021