Summary for Test 2021-11-16-6-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 214710
DEA: 051J4704
EFIS: 0517000184
DIST-CO-RTE-PM05-SB-135-17.3/17.6
Award Date05/27/2021
Closeout Date08/17/2022
Work DescriptionBUNNY AVENUE AND NORTH BROADWAY PED IMPROVEMENTS
Location DescriptionSANTA BARBARA COUNTY IN SANTA MARIA AT BUNNY AVENUE AND FROM ROEMER WAY TO PREISKER LANE
QA Service Level1 (Verified on 02/20/2020)

Sample Information

Sample Taken Date11/16/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/18/2021
Sample typeAcceptance A brief description of the sampleNative Soil
The quantity of what the sample constitutes139.2 sqyd From where was the sample collectedJob Site
First name of sampler or witnessed bysalvador Last name of sampler or witnessed bylopez-zamora
Title of samplerARET Telephone number of sampler8057483854
Laboratory sample identification334 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNative Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleNative Soil
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedRoadway BR1 10600 to 10779
Where the material sample would have been placed if not sampledRoadway BR1 10600 to 10779

Test Details

DIME Sample ID: 2021-11-16-6
DIME Test ID: 2021-11-16-6-2
Testing Lab: CT D05 - Santa Maria Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2021-11-17

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Salvador Lopez-Zamora
Date of test: 11/16/2021
Gage No.: 30590
Test No.: 004 retest
Nuclear By: Salvador Lopez-Zamora
Non-Bias Plan No.: no data
Depth: 8
Material No.: no data
Material Type: Native
Impact By: Salvador Lopez-Zamora
Standard Count Density: 1744 g/cc
Count or Density 1: 888 g/cc
Count or Density 2: 918 g/cc
Count or Density 3: 1188 g/cc
Standard Count Moisture: 633 g/cc
Moisture Count 1: 136 g/cc
Moisture Count 2: 154 g/cc
Moisture Count 3: 145 g/cc
Sum of Count or Density: 2994.00 g/cc
Average of Count or Density: 998.00 g/cc
Sum of Moisture Count: 435.00 g/cc
Average of Moisture Count: 145.00 g/cc
Count Ratio Density: 0.57
Count Ratio Moisture: 0.23
Calculated Percent Relative Compaction: 95.4 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters): Retest .1

Test was verified on 11/17/2021