Summary for Test 2021-11-02-26-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 215424 DEA: 024G4404 EFIS: 0214000013 |
---|---|
DIST-CO-RTE-PM | 02-SIS-3-38.0/38.6 |
Award Date | 04/05/2021 |
Closeout Date | 08/14/2023 |
Work Description | BRIDGE REPLACEMENT |
Location Description | SISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD |
QA Service Level | 1 (Verified on 01/19/2021) |
Sample Information
Sample Taken Date | 11/02/2021 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/02/2021 |
Sample type | Department Acceptance | A brief description of the sample | 1/2 inch RAP |
The quantity of what the sample constitutes | PSE | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Clint | Last name of sampler or witnessed by | Rogers |
Title of sampler | PI | Telephone number of sampler | |
Laboratory sample identification | D78971 | Linked DIME Sample ID | 2021-11-02-25, 2021-11-02-27 |
The fabricator/manufacturer/facility name | Tullis Inc Shasta Ranch Agg Anderson Ca | Transportation Laboratory (TL) Number | 853086 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt |
---|---|---|---|
Aggregate Size | 1/2 inch | Aggregate Source | Unknown |
RAP Stockpile | Continuous | Stockpile Size (tons) | Unknown |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-02-26
DIME Test ID: 2021-11-02-26-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-11-19
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 11/17/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.5 grams
Mass of oven-dry sample in air for Sample 1: 1625.7 grams
Mass of container filled with the sample and water for Sample 1: 8316.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.516
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/19/2021 ✔