Summary for Test 2016-01-12-1-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 7463 DEA: 042640U4 EFIS: 0412000195 |
---|---|
DIST-CO-RTE-PM | 04-SON-101-0.9/3.6 |
Award Date | 11/02/2012 |
Closeout Date | 06/03/2020 |
Work Description | CONSTRUCT PETALUMA BLVD SOUTH INTERCHANGE, REPLACE PETALUMA RIVER BR |
Location Description | SONOMA COUNTY IN AND NEAR PETALUMA FROM GUNN DRIVE TO ROUTE 101/116 SEPARATION AND OVERHEAD |
QA Service Level | 1 (Verified on 09/11/2012) |
Sample Information
Sample Taken Date | 01/12/2016 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2016 |
Sample type | Quality Assurance | A brief description of the sample | 2 6x12 concrete cylinders |
The quantity of what the sample constitutes | 7 CY End Cap P3 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Harry | Last name of sampler or witnessed by | Suryantoro |
Title of sampler | TEC | Telephone number of sampler | 510) 385-7179 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Shamrock | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Petaluma River Bridge |
Material Information
Material Type | Concrete | The concrete mix design number | 4100A |
---|---|---|---|
The truck number from where the sample was collected | 1288 | The batch plant ticket number from where the sample was collected | 434427 |
Concrete batch plant | 04 | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | Pier 3 End Cap West |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2016-01-12-1
DIME Test ID: 2016-01-12-1-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-02-08
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM TTO
Date of test: 02/08/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.96 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 144578 lb
Maximum load on cylinder 2: 156458 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 27 days
Cross sectional area of cylinder 1: 27.9 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 5182.0 psi
Compressive strength of cylinder 2: 5569.9 psi
Compressive strength (to nearest 10 psi): 5380 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 2/8/2016 ✔