Summary for Test 2016-01-22-5-1
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/22/2016 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/28/2016 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 43 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | S333623-2 S333627-2 S333627-5 S333631-5 S333635-5 S333641-3 S333642-1 S333645-3 S333645-4 S333646- 2 S333646-7 S333649- 2 S333652-1 S333653-1 S333653- 2 S333654-2 S333654-3 S377400-3 S377400-5 S377414-4 | Number of Coils | 20 |
Group Number | 10838 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0585015 S0585215 S0584115 S0584515 S0584715 S0584215 S0584615 S0585315 S0595115 S0585115 S0584415 S0584315 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden |
Test Details
DIME Sample ID: 2016-01-22-5
DIME Test ID: 2016-01-22-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Test Release Date: 2016-02-03
Test Results
Number of Samples: 20
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 02/01/2016
Num | Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) |
---|---|---|---|---|---|---|---|---|
1 | .207 | .196 | .196 | .196 | .196 | .196 | .196 | 0.215 |
2 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
3 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
4 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
5 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
6 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
7 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
8 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
9 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
10 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
11 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
12 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
13 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
14 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 |
15 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 |
16 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
17 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 |
18 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 |
19 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 |
20 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/3/2016 ✔