Summary for Test 2021-07-29-52-7
Test performed: AASHTO T48-18Project Information
Project Identifiers | Project ID: 215590 DEA: 112N0414 EFIS: 1118000184 |
---|---|
DIST-CO-RTE-PM | 11-IMP-115-R8.8/L11.4 |
Award Date | 06/10/2021 |
Closeout Date | 05/10/2022 |
Work Description | COLD PLANE, PAVE WITH HMA, PLACE MICROSURFACING AND SHOULDER BACKING. |
Location Description | IMPERIAL COUNTY IN AND NEAR HOLTVILLE FROM TOWLAND ROAD TO WEST JUNCTION EVAN HEWES HIGHWAY. |
QA Service Level | 1 (Verified on 07/23/2021) |
Sample Information
Sample Taken Date | 07/29/2021 | Sample Unique Key | 52 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/14/2021 |
Sample type | Acceptance | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | N/A | Last name of sampler or witnessed by | N/A |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | C963255 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Wilmington CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-29-52
DIME Test ID: 2021-07-29-52-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2021-11-12
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 10/27/2021
Observed Flash Point: 307 C
Ambient Barometric Pressure: 963 mmHg
Cleveland Open-Cup Flash Point in Celsius: 307 C
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/12/2021 ✔