Summary for Test 2021-10-28-30-3
Test performed: ASTM C293-10Project Information
Project Identifiers | Project ID: 215556 DEA: 081L6504 EFIS: 0820000131 |
---|---|
DIST-CO-RTE-PM | 08--,58- |
Award Date | 06/18/2021 |
Closeout Date | 04/08/2022 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 10/28/2021 | Sample Unique Key | 30 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/28/2021 |
Sample type | Quality Assurance | A brief description of the sample | PCC Rapid set beams |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Larry | Last name of sampler or witnessed by | Francisco |
Title of sampler | te | Telephone number of sampler | |
Laboratory sample identification | 10082021-SET NO 9 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | FEC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | RTE 58 EB LN 2 PM 16dot 7 |
Material Information
Material Type | Concrete | The concrete mix design number | SM446BR2 |
---|---|---|---|
The truck number from where the sample was collected | NA | The batch plant ticket number from where the sample was collected | NA |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | AT THE JOB SITE | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-10-28-30
DIME Test ID: 2021-10-28-30-3
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: ASTM C293-10: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam With Center-Point Loading)
Test Release Date: 2021-11-08
Test Results
Unit system used?: US Units
Input Type: Calculated
Tester's full name: larry Francisco
Date of test: 11/07/2021
Identification number: 9F
Width of specimen: 6 inch
Depth of specimen: 6.08 inch
Span length of specimen: 18 inch
Maximum load applied: 9900 lb
Curing history and apparent moisture condition of the specimen: SAND PITS
If specimen was capped, ground or if leather shims were used: NO
Defects in specimen: NO
Age of specimen: 10 days
Modulus of rupture: 840 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/8/2021 ✔