Summary for Test 2021-08-09-47-8

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/09/2021 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/23/2021
Sample typeVerification A brief description of the samplePG58-16 Asphalt Binder
The quantity of what the sample constitutes2 of 2 cans From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byConner
Title of sampler Sr Asphalt Technician Telephone number of sampler6614327352
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery, Bakersfield, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-09-47
DIME Test ID: 2021-08-09-47-8
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-11-05

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 11/03/2021
Ductility of test #1 (D1): 95 cm
Ductility of test #2 (D2): 90 cm
Ductility of sample: 93 cm
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specs

Test was verified on 11/5/2021