Summary for Test 2015-12-08-3-2

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 210088
DEA: 074X3804
EFIS: 0715000168
DIST-CO-RTE-PM07-LA-110-23.2/23.7
Award DateNot set
Closeout DateNot set
Work DescriptionRepair damaged highway and roadside facility
Location DescriptionLA-110 at the 101/10 & 5 connectors , in downtown LA
QA Service Level1 (Verified on 12/03/2015)

Sample Information

Sample Taken Date12/08/2015 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/15/2015
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinder 6 x 12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGizachew Last name of sampler or witnessed byAbayneh
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification928-C3 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameLEHIGH Transportation Laboratory (TL) NumberA1B2C3
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design number557237SP
The truck number from where the sample was collected331 The batch plant ticket number from where the sample was collected4E07
Concrete batch plantUnknown The fabricator/manufacturer designation for the samplePlant
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledNB 110 RIGHT POST STA 1242 plus 30
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-12-08-3
DIME Test ID: 2015-12-08-3-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-01-05

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 01/05/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 133130 lb
Maximum load on cylinder 2: 135100 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 4739.4 psi
Compressive strength of cylinder 2: 4809.5 psi
Compressive strength (to nearest 10 psi): 4770 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/5/2016