Summary for Test 2021-10-13-2-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214402 DEA: 010E7704 EFIS: 0115000009 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-R17.9/87.8 |
Award Date | 01/21/2020 |
Closeout Date | 07/21/2023 |
Work Description | STRENGTHEN 2 BRIDGES. |
Location Description | HUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD |
QA Service Level | 1 (Verified on 09/16/2019) |
Sample Information
Sample Taken Date | 10/13/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/27/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1" x 4 1/2" A325 bolts nuts and washers |
The quantity of what the sample constitutes | 581 fastener assemblies | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-090-21 | Structure unique identifier | |
Structure name | Unknown |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 457463A |
---|---|---|---|
Heat Number(s) | Bolt- 100109948 Nut- 8000007906 washer- 32023170 | Nut Mfg. Lot Number(s) | Nucor- 455386A |
Washer Mfg. Lot Number(s) | Prestige- D9793 | Bolt Specification | A325 type 1 |
Bolt Length(s) | 4 1/2" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1"x 4 1/2" | Bolt Mfg. Lot Number | Nucor- 457463A |
Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
Test Details
DIME Sample ID: 2021-10-13-2
DIME Test ID: 2021-10-13-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-11-03
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/29/2021
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 457463A | 1.0000 | 87563 | 389.5 | 10.00 | A325 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point FileTest was verified on 11/3/2021 ✔