Summary for Test 2021-10-13-10-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214402
DEA: 010E7704
EFIS: 0115000009
DIST-CO-RTE-PM01-HUM-101-R17.9/87.8
Award Date01/21/2020
Closeout Date07/21/2023
Work DescriptionSTRENGTHEN 2 BRIDGES.
Location DescriptionHUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
QA Service Level1 (Verified on 09/16/2019)

Sample Information

Sample Taken Date10/13/2021 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/27/2021
Sample typeQuality Assurance A brief description of the sample1" x 3 1/4" A325 bolts nuts and washers
The quantity of what the sample constitutes44 fastener assemblies From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Telephone number of sampler510-376-7155
Laboratory sample identification Linked DIME Sample ID2021-10-13-2
The fabricator/manufacturer/facility nameCK Johnson Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB9-090-21 Structure unique identifier
Structure nameUnknown

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)454040A
Heat Number(s)Bolt- 100109032 Nut- 8000007906 washer- 32023170 Nut Mfg. Lot Number(s)Nucor- 455386A
Washer Mfg. Lot Number(s)Prestige- D9793 Bolt SpecificationA325 type 1
Bolt Length(s)3 1/4" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1"x 3 1/4" Bolt Mfg. Lot NumberNucor- 454040A
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes

Test Details

DIME Sample ID: 2021-10-13-10
DIME Test ID: 2021-10-13-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-11-03

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/29/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11455386A94672A563fsaylor

General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 11/3/2021