Summary for Test 2021-06-30-47-2

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/30/2021 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/25/2021
Sample typeInformational A brief description of the sample3/4" (Drum Plant)
The quantity of what the sample constitutes6 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byHarish Last name of sampler or witnessed byThakur
Title of samplerTET Telephone number of sampler
Laboratory sample identification21-JMF-0185 Linked DIME Sample ID2021-06-30-31
The fabricator/manufacturer/facility nameGranite Construction Vernalis Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0002::VERNALIS
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-30-47
DIME Test ID: 2021-06-30-47-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2021-10-29

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 10/27/2021
Mass of fractured, coarse, 2 faced particles tested: 1217.7 g
Mass of questionable, coarse, 2 faced particles tested: 46.4 g
Mass of unfractured, coarse, 2 faced particles tested: 98.8 g
Mass of fractured, coarse, 1 faced particles tested: 1131 g
Mass of questionable, coarse, 1 faced particles tested: 39.5 g
Mass of unfractured, coarse, 1 faced particles tested: 47.2 g
Percentage of questionable, coarse, 2 faced particles tested: 3 %
Percentage of questionable, coarse, 1 faced particles tested: 3 %
Percentage of fractured, coarse, 2 faced particles tested: 91 %
Percentage of fractured, coarse, 1 faced particles tested: 95 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/29/2021