Summary for Test 2015-12-23-3-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 208967
DEA: 110223U4
EFIS: 1112000102
DIST-CO-RTE-PM11-SD-5,89-R29.1/R30.5
Award Date12/18/2014
Closeout Date02/04/2022
Work DescriptionREPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT
QA Service Level1 (Verified on 01/21/2015)

Sample Information

Sample Taken Date12/23/2015 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/30/2015
Sample typeQuality Assurance A brief description of the sampleCoupon Casting
The quantity of what the sample constitutes2 From where was the sample collectedDistributor
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBCI Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)11175, 11195
Part Number (s)6827216246 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)BCI
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2015-12-23-3
DIME Test ID: 2015-12-23-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-01-05

Test Results


Number of Samples: 4
Input Type: Calculated
Tester's full name: Fred
Date of test: 12/31/2015
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1111750.50.1963655451138509.6Fred
2111750.50.1963572449817010Fred
3111950.50.19636456511164010.4Fred
4111950.50.19636618911379010.2Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 1/5/2016