Summary for Test 2021-10-22-3-9

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 212252
DEA: 033F5604
EFIS: 0313000033
DIST-CO-RTE-PM03-SUT,YUB-20-17.0/17.1,0.0/0.4
Award Date02/11/2021
Closeout Date01/25/2023
Work DescriptionINSTALL CAST-IN-STEEL SHELL CONCRETE PILE.
Location DescriptionSUTTER AND YUBA COUNTIES IN YUBA CITY AND MARYSVILLE AT THE FEATHER RIVER BRIDGE AND OVERHEAD
QA Service Level1 (Verified on 04/27/2018)

Sample Information

Sample Taken Date10/22/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/25/2021
Sample typeQuality Assurance A brief description of the sample#7 T- heads 555
The quantity of what the sample constitutes2275 t-heads From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Telephone number of sampler510-376-7155
Laboratory sample identification Linked DIME Sample ID2021-10-19-3
The fabricator/manufacturer/facility nameConco Reinforcing Benicia Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB9-106-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)260421 Head Manufacturer Lot Number(s)grp 06 T21, grp07 T26, grp 08 T31, grp 09 T36
Rebar Size#7 Headed Bar Model Name555 T Heads
Size of HeadFull Size - 9x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerCascade Steel
Head ManufacturerConco Machine 1 Head FabricatorConco
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2021-10-22-3
DIME Test ID: 2021-10-22-3-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-10-28

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/27/2021
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1310.65801696694OK Neckingbewing

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/28/2021