Summary for Test 2021-09-25-12-1

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 215753
DEA: 050N72U4
EFIS: 0520000169
DIST-CO-RTE-PM05-SB-101-4.4/R7.7
Award Date03/01/2021
Closeout DateNot set
Work DescriptionPlease cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description101 freeway in Summerland, CA
QA Service Level1 (Verified on 05/06/2021)

Sample Information

Sample Taken Date09/25/2021 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/25/2021
Sample typeQuality Control A brief description of the sampleCT 7.18 C+F25% 1"/PGUHR 4p00 in
The quantity of what the sample constitutes8 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byTim Last name of sampler or witnessed byReyes
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHanson - Goleta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number7254A1Z0P
The truck number from where the sample was collected550 The batch plant ticket number from where the sample was collected550027
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedHwy 101 Media Toro Cyn Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-09-25-12
DIME Test ID: 2021-09-25-12-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2021-10-26

Test Results


Number of specimens: 4
Input Type: Calculated
Tester's full name: Tim Reyes
Date of test: 10/25/2021
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): 2
Break Description of Cylinder 2 (if not 'cone'): 2
Break Description of Cylinder 3 (if not 'cone'): 2
Break Description of Cylinder 4 (if not 'cone'): 2
Average Compressive Strength (to nearest 10): 6070 lb/in^2
Compressive Strength of Cylinder 1: 3606 lb/in^2
Compressive Strength of Cylinder 2: 5085 lb/in^2
Compressive Strength of Cylinder 3: 5631 lb/in^2
Compressive Strength of Cylinder 4: 6062 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/26/2021