Summary for Test 2021-10-15-22-1
Test performed: ASTM C566-19Project Information
Project Identifiers | Project ID: 209820 DEA: 04297634 EFIS: 0415000040 COOP: 042548 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84,680-17.9/21 |
Award Date | 02/19/2021 |
Closeout Date | Not set |
Work Description | ROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION. |
Location Description | ALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84 |
QA Service Level | 1 (Verified on 11/04/2019) |
Sample Information
Sample Taken Date | 10/15/2021 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/15/2021 |
Sample type | Quality Control | A brief description of the sample | Course aggregate |
The quantity of what the sample constitutes | 1 days production | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Wally | Last name of sampler or witnessed by | Bucaneg |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Forterra Pipe and Precast Florin Rd | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-34-0045::ASPEN IV SOUTH |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | conveyor | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-10-15-22
DIME Test ID: 2021-10-15-22-1
Testing Lab: Rinker Materials
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Test Release Date: 2021-10-22
Test Results
Input Type: Calculated
Tester's full name: Wally Bucaneg
Date of test: 10/15/2021
Total evaporable moisture content: 4.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/22/2021 ✔