Summary for Test 2021-09-17-37-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215168
DEA: 101C5004
EFIS: 1016000026
DIST-CO-RTE-PM10-SJ-4,5-T15.5/R16.7,25.8/26.5
Award Date12/09/2020
Closeout Date09/14/2023
Work DescriptionCONSTRUCT JPCP, CRCP, AND APPROACH SLABS.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON ON ROUTE 4 FROM 0.2 MILE EAST OF FRESNO AVENUE TO EL DORADO STREET AND ON ROUTE 5 FROM TAYLOR STREET OVERHEAD TO STOCKTON CHANNEL VIADUCT
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date09/17/2021 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2021
Sample typeAcceptance A brief description of the sampleBINDER
The quantity of what the sample constitutes2 CANS From where was the sample collectedSource
First name of sampler or witnessed byAdam Last name of sampler or witnessed byZ
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero Transportation Laboratory (TL) Number034307
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number1
Sublot number1 Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-09-17-37
DIME Test ID: 2021-09-17-37-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-22

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: eva torres
Date of test: 10/21/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 37.500 kPa
Phase Angle (δ) (for the 10 cycles): 51.8 degree
Complex Modulus (G*) (for the 10 measurements): 3749.575 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 2947 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications PAV

Test was verified on 10/22/2021