Summary for Test 2021-10-05-36-3

Test performed: CTM 533-June 2010

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout DateNot set
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date10/05/2021 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/06/2021
Sample typeAcceptance A brief description of the sampleConcrete beams
The quantity of what the sample constitutes4 Beams From where was the sample collectedJob Site
First name of sampler or witnessed byNathan / Zachariah Last name of sampler or witnessed byOgbasellasie/ Roush
Title of sampler Telephone number of sampler
Laboratory sample identification2JA1, 2JA2, 2JB1, 2JB2 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex, Fontana Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1605762
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTTI
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-10-05-36
DIME Test ID: 2021-10-05-36-3
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Test Release Date: 2021-10-18

Test Results


Input Type: Calculated
Tester's full name: N. Ogbasellasie/ Z. Roush
Date of test: 10/05/2021
Ball penetration in freshly mixed concrete (average): 1.75 inch
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/18/2021